The CADD-Solis pump is a portable, battery-operated ambulatory infusion pump designed for accurate and reliable medication delivery. It offers ease of use and versatility for various clinical settings.
1.1 Overview of the CADD-Solis Pump
The CADD-Solis pump is a lightweight, portable infusion device designed for ambulatory use, offering precise medication delivery. Its compact design and intuitive interface simplify operation. The pump supports multiple delivery modes, including continuous and PCA, and integrates seamlessly with administration sets. It ensures safe, reliable, and efficient therapy management in various clinical settings.
1.2 Importance of the User Manual
The user manual is essential for safe and effective use of the CADD-Solis pump. It provides detailed instructions for programming, troubleshooting, and maintaining the device. Clinicians must follow the guidelines to ensure proper operation, prevent malfunctions, and avoid patient harm. The manual also outlines safety precautions and contraindications, making it a critical resource for healthcare professionals.
Table of Contents
This manual provides a comprehensive guide to the CADD-Solis pump, covering installation, safety precautions, operating modes, troubleshooting, and maintenance. It ensures proper use and optimal performance of the device.
2.1 List of Sections in the Manual
2.2 Key Topics Covered
The manual covers essential topics such as pump setup, safety precautions, operating modes, programming, alarms, and maintenance. It also includes guidance on troubleshooting, battery management, and security features. Additional sections focus on advanced settings, technical specifications, and support resources, ensuring comprehensive understanding and safe operation of the CADD-Solis pump for healthcare professionals.
System Requirements
The CADD-Solis pump requires compatible hardware and software specifications to ensure optimal performance. It must be used with approved medical equipment and accessories for safe operation.
3.1 Hardware and Software Specifications
The CADD-Solis pump operates on 4 AA batteries or an external battery pack. It requires compatible administration sets and tubing for proper function. Software specifications ensure accurate delivery rates and mode settings. Always use approved accessories and refer to the manual for detailed compatibility and configuration guidelines to maintain optimal performance and safety.
3.2 Compatibility with Medical Equipment
The CADD-Solis pump is designed to work seamlessly with standard medical equipment, including IV administration sets and tubing. Ensure compatibility with external devices like fluid bags and extension lines. Verify all components meet Smiths Medical specifications to maintain safe and accurate operation. Always use approved accessories to prevent interference or malfunction during therapy delivery.
Installation and Setup
Unpack the pump, insert batteries, and turn it on. Follow on-screen prompts to configure settings and prepare for patient use.
4.1 Unpacking and Preparing the Pump
Carefully unpack the CADD-Solis pump and inspect for damage. Remove all packaging materials and ensure all accessories, such as administration tubing, are included. Place the pump on a flat surface and prepare it for use by ensuring the keypad is accessible and the battery compartment is ready for insertion.
4.2 Inserting Batteries and Turning On the Pump
Insert four fresh AA batteries into the battery compartment, ensuring correct polarity. Gently close the compartment. Press the power switch to turn the pump on. The keypad will light up, and the system will perform a self-test. Once complete, the pump is ready for initial configuration. If the keypad is locked, use the keypad code to unlock it.
4.3 Initial Configuration and Settings
After turning on the pump, it performs a self-test. Select “Yes” to start a new patient profile. Set the date and time, then enter the infusion parameters such as rate and volume. Review all settings to ensure accuracy. Save the configuration to begin operation. The pump is now ready for use with the programmed settings applied to the patient profile. Proper setup ensures safe and accurate therapy delivery.
Safety Precautions
Follow all warnings and cautions. Manual for clinicians only; do not permit patient access. Not for blood or cellular blood products. Proper use essential for safety.
5.1 Warnings and Cautions for Safe Operation
The CADD-Solis pump is for single-patient use only. Ensure proper training before operation. Misuse can cause serious injury or death. Do not use for blood or cellular products. Always follow warnings and cautions in this manual. Improper use or disregard of safety guidelines may result in patient harm. Use only as prescribed by a healthcare professional.
5.2 Contraindications for Use
The CADD-Solis pump is contraindicated for use with blood or cellular blood products. It should not be used for medications requiring precise temperature control or for patients with known allergies to pump components. Misuse or improper setup can lead to serious injury or death. Always adhere to the clinical guidelines and manufacturer instructions for safe operation.
Operating Modes
The CADD-Solis pump features two primary operating modes: Continuous Rate and Patient-Controlled Analgesia (PCA). These modes ensure precise and flexible medication delivery for various clinical applications.
6.1 Continuous Rate Mode
The Continuous Rate Mode delivers medication at a constant, pre-programmed rate, ideal for steady infusion needs. Clinicians can set precise mL/hr rates, ensuring consistent therapy. This mode is suitable for patients requiring uninterrupted medication flow, with the pump maintaining the specified rate until programmed to stop or adjusted by authorized personnel.
6.2 Patient-Controlled Analgesia (PCA) Mode
The PCA Mode allows patients to self-administer bolus doses of medication within set limits, providing pain relief on demand. Clinicians program the bolus dose size, lockout interval, and maximum doses per hour. This mode enhances patient comfort while maintaining safety by preventing overdosing. The pump logs all deliveries for monitoring, ensuring precise control over analgesia administration.
Programming the Pump
Programming the CADD-Solis pump involves setting up patient profiles, adjusting delivery parameters, and securing settings. Clinicians can customize infusion rates, bolus doses, and lockouts to meet individual needs, ensuring accurate and safe medication delivery.
7.1 Setting Up a New Patient Profile
To set up a new patient profile, enter the patient’s identification and medical details. Configure infusion parameters such as rate, dose, and duration. Review all settings for accuracy. Secure the profile with a keypad code to prevent unauthorized changes, ensuring patient safety and precise medication delivery.
7.2 Adjusting Delivery Parameters
Adjust delivery parameters by accessing the keypad-secured menu. Modify infusion rates, volumes, and times as needed. Ensure settings align with prescribed therapy. Review changes for accuracy before saving. Use the keypad code to confirm adjustments, maintaining patient-specific delivery protocols and ensuring precise medication administration.
7.3 Locking and Unlocking the Keypad
To lock the keypad, press and hold the Stop/Start button until “Locked” appears. Enter the keypad code to unlock. This feature prevents unauthorized changes to delivery parameters, ensuring patient safety. Always lock the keypad after adjustments to maintain secure operation and prevent accidental modifications. Refer to the manual for detailed instructions;
Alarms and Troubleshooting
The pump alerts users with specific alarms for issues like air in the line or occlusions. Refer to the manual for troubleshooting steps to resolve these alarms quickly and ensure continuous operation.
8.1 Common Alarms and Solutions
The CADD-Solis pump alerts users with specific alarms, such as Air in Line, Low Battery, or Occlusion. To resolve these, acknowledge the alarm, check for air bubbles, ensure proper tubing connections, or replace batteries. Restarting the pump after addressing the issue typically clears the alarm, ensuring uninterrupted medication delivery. Refer to the manual for detailed troubleshooting steps to quickly address and resolve these common alarms effectively.
8.2 Resolving the “Air in Line” Alarm
To resolve the Air in Line alarm, select Acknowledge to clear it. Close the clamps and disconnect the fluid path if air bubbles are present. Prime the tubing to remove air, ensuring no bubbles remain. Restart delivery only after confirming the fluid path is clear. This process stops the alarm and ensures proper pump operation. Always follow manual guidelines for accurate troubleshooting.
8.3 Troubleshooting Battery Issues
For battery issues, ensure batteries are installed correctly with proper orientation. Use fresh AA batteries or a charged external pack. If the pump doesn’t turn on, check for corrosion or incorrect placement. Restart the pump after replacing batteries. If problems persist, contact Smiths Medical support. Note: The pump lacks an alarm for improperly installed batteries, so verify placement carefully.
Maintenance and Care
Regularly clean the pump with a damp cloth and avoid harsh chemicals. Inspect for wear and tear, and replace accessories as needed to ensure optimal performance.
9.1 Cleaning the Pump
Regular cleaning is essential for maintaining the pump’s performance. Use a soft, damp cloth to wipe down the exterior, avoiding harsh chemicals or abrasive materials. Ensure no moisture enters the pump’s openings. Allow the pump to air dry completely before use or storage. This helps prevent damage and ensures optimal functionality over time.
9.2 Replacing Batteries and Accessories
Turn off the pump and remove old batteries. Insert four new AA batteries, ensuring correct polarity. For accessories, replace administration sets and tubing as needed. Use only compatible parts to maintain performance. Regularly check for wear and tear. Replace any damaged components immediately to ensure safe and accurate medication delivery. Always follow manufacturer guidelines for replacement procedures.
Optional Accessories
Optional accessories include external battery packs for extended use and administration sets with tubing. These enhance functionality and customize the pump for specific patient needs.
10.1 External Battery Packs
External battery packs extend the pump’s operation time, providing reliable power for continuous therapy. They are rechargeable and compatible with the CADD-Solis pump, offering flexibility for long-term use. Ensure proper installation, as no alarm alerts for incorrect battery placement. Refer to the manual for installation steps and compatibility guidelines to maintain optimal performance and patient safety.
10.2 Administration Sets and Tubing
Administration sets and tubing are essential for delivering medication accurately. Use only compatible Smiths Medical sets to ensure safety and performance. Remove tubing from packaging, take off any tape, and close the pinch clamp. Detach the blue plastic clip from the cassette before use. Proper handling prevents air bubbles and ensures precise fluid delivery, as outlined in the manual for optimal patient care.
Keypad Code and Security
The keypad code ensures secure access to patient-specific parameters and settings. Clinicians use this code to modify settings and manage air and occlusion parameters safely and effectively.
11.1 Understanding the Keypad Code
The keypad code is a security feature designed to protect patient-specific parameters from unauthorized access. Clinicians use this code to modify settings, ensuring only approved personnel can alter configurations. It enhances safety by preventing accidental or unintended changes to infusion settings, maintaining precise control over medication delivery and patient care. This feature is essential for safeguarding patient information and ensuring operational integrity.
11.2 Securing Patient-Specific Parameters
The CADD-Solis pump allows clinicians to secure patient-specific parameters using a keypad code, ensuring only authorized personnel can modify settings. Once locked, these parameters cannot be altered without the code, preventing accidental changes. This feature enhances patient safety by maintaining consistent and accurate infusion delivery, reducing risks associated with unauthorized adjustments. It also ensures compliance with clinical protocols and patient care standards.
Advanced Features
The CADD-Solis pump offers advanced features like the Device Information Screen, displaying serial number, software, and hardware details. Software updates ensure optimal performance and compatibility.
12.1 Device Information Screen
The Device Information Screen displays the pump’s serial number, software version, and hardware details. This feature helps clinicians verify the pump’s configuration and ensures compatibility with updates. It also aids in troubleshooting by providing precise technical specifications for support. Accessing this screen ensures accurate device identification and maintenance, making it a crucial tool for healthcare professionals. It enhances operational transparency and efficiency.
12.2 Software Version and Updates
Regular software updates ensure the CADD-Solis pump operates with the latest features and security patches. Clinicians can check the current software version on the Device Information Screen. Updates are typically managed by the system administrator. Users should contact Smiths Medical or refer to the manual for guidance on updating the pump’s software to maintain optimal functionality and compliance with safety standards.
Technical Specifications
The CADD-Solis pump is a compact, lightweight device designed for precise fluid delivery. Its technical specs ensure reliable performance, with accurate medication administration and durable construction for clinical use.
13.1 Pump Dimensions and Weight
The CADD-Solis pump is designed to be portable and compact, measuring approximately 4.5 inches in height, 3.5 inches in width, and 2.5 inches in depth. Weighing around 12 ounces, it is lightweight and easy to carry, making it ideal for ambulatory use without compromising on functionality or performance.
13.2 Fluid Delivery Accuracy
The CADD-Solis pump ensures precise fluid delivery, maintaining accuracy within ±5% of the set rate. It consistently delivers medication across various flow rates, providing reliable performance for both continuous and intermittent infusions. This accuracy is crucial for patient safety and effective therapy outcomes, making the pump a trusted choice in clinical settings.
Smiths Medical Support
Smiths Medical offers 24/7 assistance for CADD-Solis pump programming and operation. Contact their support team for help, ensuring optimal device performance and patient care.
14.1 Contact Information
For assistance with the CADD-Solis pump, contact Smiths Medical at their 24/7 support line. Call the provided number, specifying the pump’s software version for accurate help. Email support is also available for troubleshooting and programming guidance. Ensure to have your pump’s serial number ready for efficient assistance. Visit their website for additional contact options and updated resources.
14.2 Availability of Assistance
Smiths Medical provides 24/7 support for the CADD-Solis pump. Assistance is available via phone or email, ensuring help is accessible whenever needed. Representatives are ready to address programming, operation, or troubleshooting inquiries. For efficient support, have the pump’s serial number and software version available. This ensures prompt resolution to any issues, maintaining seamless patient care and device functionality.
The CADD-Solis pump is a reliable, portable solution for medication delivery, offering precise control and user-friendly operation. Adhere to guidelines for optimal use and patient safety.
15.1 Summary of Key Points
The CADD-Solis pump is a portable, user-friendly device for precise medication delivery. Proper setup, safety precautions, and regular maintenance are crucial. Understanding operating modes, programming options, and troubleshooting steps ensures optimal use. Always refer to the manual for detailed guidance, and contact Smiths Medical for assistance. Adherence to guidelines enhances patient safety and device performance.
15.2 Final Tips for Effective Use
Always ensure proper tubing connections and check for air bubbles before starting. Regularly clean the pump and replace batteries as needed. Use the keypad code to secure settings and prevent unauthorized changes. Double-check all parameters before initiating infusion. Keep the user manual handy for quick reference. For complex issues, contact Smiths Medical support for assistance.